3 in 1 Rework Station MS-300
- z One-stop tool set, unified appearance, let desktop clean and tidy.
- It can be divided into independent stations, which is more convenient and practical.
- Unique PC area with adjustable holder, convenient for technicians to check files.
- Large LCD make control visualization; MCU control data more stable and accurate.
- Soldering station has over temperature alarm, auto-sleep, shortcut temperature.
- Hot air station used high-power brushless fan with strong wind and low noise.
- Unique designed straight and cyclone nozzles for beginners and professionals.
- Unique handle button start/stop function makes the use safer.
- Hot air station has timing, cold air, auto sleep, temperature preset & lock, password protect functions, which can handle most of soldering/desoldering task.
- DC power supply has dual displays and USB interface.
- Power supply use series linear regulation scheme, which has good reliability and low ripple, no interference, no leakage current.
- It’s more suitable for the test and maintenance of precision products.
♦ Easy Temperature Setting
Under normal work, press “▲” or “▼” button to adjust temperature value. Long pressing can be quickly adjusted. After stop pressing for 3 seconds to save the data. (The temperature value cannot be adjusted when it’s locked.)
♦ Save or recall frequently used temperature.
Press “1 or 2 or 3” button to quickly preset temperature value; Long press “1 or 2 or 3” button ( more than 3 seconds ) to store temperature value.
♦ Temperature lock function
Under the Loc menu, press “▲” and “▼” button to turn on/off. [1] [3] button to switch menus up and down, [2] button to exit and save settings.
♦ ℃/℉is available and exchangeable.
Under C-F menu, press“▲” and “▼” button to exchange temperature unit.
♦ Temperature calibration
Under the CAL menu, press the “▲” and “▼” button to adjust the value. Calibration range [-50 ℃ ~ 50 ℃ (-90℉ ~ 90℉)]. When the real temperature is lower than the display temperature, the compensation takes a negative temperature value. When the real temperature is higher than the display temperature, take a positive temperature value.
♦ Auto-sleep function
Under the SLP menu, press “▲” and “▼” to set the sleep parameter Off/On time: 10~60 minutes (default 10). The heating element temperature is 200 °C under sleep status. In sleep mode, pick up the soldering tool or press any key to automatically resume normal operation. (Note: If the device is not in a static state, it will affect the device to enter auto sleep.)
♦ Automatically turn off the heating function
Note: automatically turn off the heating function needs to be used when the auto-sleep function is turned on. When the auto-sleep function is turned off, the automatically turn off the heating function is turned off at the same time. The automatically turn off the heating function cannot be turned off when the auto sleep function is turned on.
Under the OFF menu, press“▲” and “▼” button can set the turn-off the heating time after sleep: 10~60 (default 20) minutes. When the heating state is turned off, pressing any button will automatically resume the normal working mode.
♦ Beep alarm function available
Under the BL menu, press “▲” and “▼” button to switch the alarm function.
♦ Upper /lower temperature alarm function
Under the H-L menu, press “▲” and “▼” button to set the upper /lower temperature values and OFF. It will alarm if soldering iron temperature higher or lower then the set alarm temperature. The upper and lower temperature rang is ±20 to 80 °C.
♦ Password Protection
Under the PSD menu, press “▲” and “▼” button to adjust the password setting data. The password data can be set from “01” to “999”. Display 00 means no need password to enter the menu interface. Default no password for the first entrance. Press button 2 to enter the menu then set the password and press 2 button to save the setting.
♦ Fault alarm function
Display S-E is a sensor fault; H-E is a heater core fault.
Hot Air Station
♦ Easy Temperature Setting
Press air “▲” or “▼” key to adjust the air volume and temperature. Long press for quickly adjusting. Stop pressing the key for 3 seconds, it will save the setting automatically.
♦ The cool air function is used when the temperature setting value under 100 ℃.
♦ Saving and Call Shortcut Temperature
Press button “1”/ “2”/ “3” to call or save preset temperature and air flow value.
♦ Temperature Lock Function
Under Menu Loc, it can turn on or off temperature lock function by pressing “▲” or “▼” key; then press Button “2” to exit and save your setting.
♦ ℃/℉ available
In menu C-F mode, it can switch temperature unit ℃/℉ by pressing “▲” or “▼” key.
♦ Temperature Calibration
Under menu CAL mode, press “▲”or“▼” key to enable temperature calibration function, which calibration range is -50℃~ 50℃(-90℉~90℉). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.
♦ Beeping function
Under menu BL mode, it can turn on/ off the beeping function by pressing “▲” or “▼”key.
♦ Timing function
Under menu HTO mode, it can adjust time of timing function by pressing “▲” or “▼” key. Time range from 10 to 900 seconds.
♦ Standby Function
In menu STBY, press “▲” or “▼” can adjust standby function on or off. It can adjust the standby time from 1 to 10mins. When standby function is on, this handle can be shut off automatically when putting it on this holder. If within standby time, taking this handle out of holder it will recover to work; if beyond the standby time, it won't work until pressing the button on hot air gun. (Note: if both timing function and standby function are on simultaneously, timing function will be recount time when the hot air gun working. )
♦ Fault alarm function
E2 Sensor open circuit | Poor contact of air gun connector or handle, should replace heater. |
E3 No signal of zero-cross | The zero-cross circuit is damaged, need to repair. |
E7 Sensor short circuit | The short circuit occurs to the temperature sensor of heating element; or heating core open circuit. Should replace the heating element. |
E8 Over temperature protection | The temperature sensor is abnormal; should replace the heating core. The temperature of heating core is too high; after the heating core is cool, restart the machine. |
E10 Heater overheating | Need to repair. |
E11 Fan broken | Need to repair. |
E13: The heating output switch component was failed | Need to repair. |
♦ DC Power Supply
1. MUC control, regulating control in series, low ripple, low noise and high stability.
2. LCD and bridge-current meter display, more suitable for phone/computer repair.
3. Fast load response, specially optimized design for mobile communication equipment.
4. Over current & self-recovery protection, constant current output, over heating protection function.
5. Independent 5V USB interface, providing 2.1A current, support quick charge agreement, with over current and short circuit protection.
6. Voltage and current continuously adjustable within rated range, 2 stages current and voltage quick setting, suitable for different application.
7. Built-in voltage self-adaptive gear, which can adapt to full load working.
8. Digital encoder adjusts the voltage and can switch between coarse and fine adjustment, more precise control and longer device service life.
9. Lock output function, beep alarm function, can effectively prevent wrong operation.
10. Intelligent fan control is automatically controlled according to the temperature of the internal power supply.
♦ Specifications:
Picture |
| |||
Model | ST-862D | ST-965 | APS15-3A | |
Power | 1000W (MAX) | 65W | 56W | |
Input voltage | 110VAC/220VAC ±10% 50Hz/60Hz (optional) | 230VAC/115VAC(Optional) | ||
Temperature range | 100℃~480℃/212℉~896℉ | 200℃~450℃/392℉~842℉ | Rated output voltage | 0-5V/0-15V (dual steps) |
Temperature calibration | ±50°C/±90°F | Rated output voltage | 0-5V/0-15V (dual steps) | |
Air flow | 1-99%, 20~130L/min | Ripple and noise | CV≤0.5mVrms | |
Heating element | Pluggable | Pluggable | Protection Function | OCP(support automatically recovery)/OHP |
Soldering tip/Nozzle | 4pcs nozzles | T900-0.2IS | Other Functions | coarse tuning/ fine tuning switch, 5V/ 15 switch, 0.5A/ 3A switch and parameters locking |
Shortcut temperature/air flow | 3 sets Shortcut temperature & air flow | 3 sets Shortcut temperature | USB interface | Fixed 5V output(±5%), maximum 2.1A output (over current protection, stop outputting) |
Temperature /Air flow adjustment | Temp: 10 digits (Coarse)/1 digit (Fine-tuning)
Air: 2 digits (Coarse)/1 digit (Fine-tuning) | 10 digits (Coarse)/1 digit (Fine-tuning) | Read Back Accuracy | LCD display:±(0.5±2digits) Current pointer display: Class-2.5 |
Functions | Standby heater cooling, Beeping, Timing, Standby Auto-sleep function | Auto-sleep, Auto turn off the heating, Beeping, function | Heat-dissipating method | Smart fan control |
Working conditions | Temperature 0-40°C, relative humidity <80% | |||
Storage conditions | Temperature -20-80°C, relative humidity <80% | |||
Dimensions | 210*174*150 mm | 210*88*150 mm | 88*150*215 mm | |
Net weight | 3.34kg | 1.97kg | 2.5Kg |
♦ Packing List: |
Soldering station | ST-965 |
Hot air station | ST-862D |
DC power supply | APS15-3A |
Baffle plate | 1pc |
Fixed cover | 1pc |
connection plate | 1pc |
front baffle plate | 1pc |
plastic thumbscrews | 4pcs |
M4 flat head screw | 4pcs |
M3 flat-head screws | 3pcs |
ESD ground wire | 2pcs |
hot air gun holder | 1pc |
Soldering Iron holder | 1pc |
Soldering handle | 1pc |
3 in 1 power cord | 1pc |
Nozzles | 4pcs |
Manual | 3pcs |
Certificate of qualification | 1pc |
No reviews found