Hot Air Station ST-8800D
- Large LCD screen; Temp/Air adjust easily.
- Touch sensor inside, auto sleep function will take effect when hot air gun placed on the stand.
- Use brushless vortex fan making cyclone air output more gentle and evenly.
- Offer 4 nozzles
- Has automatic large air volume cooling function, effectively protect the life of heating core and handle.
- Has independent cold air function, can deal with special use purpose.
- Three sets of quick temperature keys, can be set and save independently, use easily.
- Has password protection and key lock function, make control easily.
- With timing function and temperature compensation function, make use flexibly.
♦ Easy Temperature/Air Flow Setting
1. Adjust the air flow value by AIR knob, "+" / "-" to increase/reduce the air volume.
2. Adjust the temperature value by pressing “▲” or “▼”, long press can be quickly adjusted.
♦ Saving and Call Shortcut Temperature
Press button “1”/ “2”/ “3” to call or save preset temperature and air flow value.
♦ Timing function
Under the HT menu, press “▲” and “▼” keys to adjust the timing function working time. The setting time is 10 - 900 seconds.
♦ Standby Function
The hot air gun stand-by function can adjust in menu, “---” means standby. The hot air gun blows at the maximum air volume when the handle is placed on the holder, then enter stand-by status when the temperature drops under 100 ° C or stop heating after 15 seconds. The machine will return to work when picking up the handle.
♦ Auto-sleep function
The hot air station will automatic enter the sleep status and display OFF after 30 minutes of no activity, and it won't re-work when the handle dropped or picked up until press any button to awaken.
♦ Temperature Lock Function
Under Loc Menu, it can turn on/off temperature lock function by pressing “▲” or “▼” key.
♦ ℃/℉ available
In menu C-F mode, it can switch temperature unit ℃/℉ by pressing “▲” or “▼” key.
♦ Temperature Calibration
Under menu CAL mode, press “▲”or“▼” key to adjust the value. Calibration range is -50℃~ 50℃(-90℉~90℉). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.
♦ Beeping function
Under menu BL mode, it can turn on/ off the beeping function by pressing “▲” or “▼”key.
♦ Password Setting Function
In PSD menu, press “▲” or “▼” to adjust password setting value, which can be set from 01 to 999. “00” means password function is off. Default no password for the first time entrance. (Note: Directly input 906 password to enter menu in case of forgot the password.)
♦ Fault alarm function
S-E | Sensor fault. |
H-E | Heating element fault. |